HIM-6000 Air Quality Monitor Print this pagePrint this page
HIM-6000 Air Quality Monitor
Price: On Request

Highlights:

> Real-Time display and data storage
> Super-large LCD display
> Easily portable and deployable
> Real-Time Wireless Data Transmission
> Easy to use Graph & Reporting Software with PC
> Can be equipped for simultaneous monitoring of EPA PM10 and PM2.5
> Sampling Rate: 1 sec, 1 min, 10 min, 1 hour (adjustable)
> Recording Time: 1 sec to 44 weeks recording time


Description
This Haz-Scanner air quality monitoring station measures and documents trace level criteria air pollutants. The portable and expandable system simultaneously measures PM 2.5 and PM 10, besides PM 1.0 and PM 4.0. The HIM-6000 offers up to 12 sensors for Toxic Volatile Organic Compounds (VOC) like H2S, SO2, O2, O3, CO2, VOC; hydrocarbons gases; barometric pressure, rain gauge; and meteorological air parameters like UV, IR, Sound, Noise, Atomic Radiation, ELF Radiation. Options include solar power, 5-mile wireless data transmission - 900MHz (US) 868MHz (Euro) and Ethernet/Internet data viewing.

Specification
Specification
Particle Size Range 1μm, 2.5μm, 4.0μm (optional), 10μm, TSP (included)
Volatile Organics (VOC) Range 0 to 50'000 ppb (0 to 50 ppm)
CH-4 Methane Range 0 to 100% volume
CO Carbon Monoxide Range 0 to 10'000 ppb (0 to 10 ppm)
NO2 Nitrogen Dioxide Range 0 to 5000 ppb (0 to 5 ppm)
SO2-Sulfur Dioxide Range 0 to 5000 ppb (0 to 5 ppm)
Sound & Noise Range 30 to 135 db
Atomic Radiation Range 1 – 19'999 cpm or 0.001 to 100 miliRad/hr
ELF Radiation Range 1 to 200 mG
Wind Speed Range/Direction 0-125 mph / 5-355 deg
Temperature Range -20ºC to 60.0ºC
Solar Irradiance 0-111 watts per square meter (w/m²)
Dew Point Range -44°C to 55.0°C
Recording Time 1 sec to 21 weeks
Sampling Rate 1 min, 10 min , 15 min, 1 hour
Data Storage 454'545 data points
Output RS232
Power 12 VDC rechargeable battery
Meter Dimensions & Weight 360 x 240 x 280 mm & 5.5 kg